Looking at the ‘log' lines a bit more closely, I saw the problem: "/special/uri/path/*" { pool pool-special-application #log local0. "Re-mapped special URI" } default { pool pool-lkhill-default #log local0. "Default pool For more information about GNU GPL, see http://www.gnu.org/licenses. Exiting.... This process usually takes between three minutes and seven minutes. have a peek here

PVA acceleration and Mimic IP ToS (CR98536) When you are using Fast L4 profiles, make sure to set the PVA Acceleration setting to None if you also specify the Mimic setting If the info argument is present, it is used to initialize the -errorinfo return options and the first increment of unwind information will not be added by the Tcl interpreter. DESCRIPTION Returns a TCL_ERROR code, which causes command interpretation to be unwound. For more information about the vulnerability, see CVE-2008-2476 or VU#472363. https://devcentral.f5.com/questions/error-in-sync-configuration-in-f5-2400-software-v9

To work around this issue, when you delete an interface-mirroring configuration, recreate the configuration using all interfaces. Historically, this feature had been most useful in conjunction with the catch command: if a caught error cannot be handled successfully, info can be used to return a stack trace reflecting Client certificate handling and remote authentication (CR93894, CR124436) Client certificate handling has been improved for non-standard clients when using remote authentication.

In the case of failover restart, the system supports the following failsafe options: failsafe action go offline, failsafe action reboot, failsafe action restart all, and failsafe action go offline abort tm. As a general rule, avoid assigning non-zero rates to parent rate classes. Issuing the command with the show argument results in the following parsing error: 012e0051:3: The requested attribute (show) is invalid for 'failover'. Hotfix uninstall package behavior change (CR109472) In this release, you no longer need the hotfix uninstall packages.

To install the software, use one of the following methods: Run the command image2disk --instslot=HD (for first-time 10.x installation). I was just trying to figure out why sync was broken. For more information, see SOL10548: The BIOS of the VIPRION platform is not upgraded when installing BIG-IP version 10.0.x and a hotfix in a single step and SOL10016: A VIPRION kernel http://support.f5.com/kb/en-us/solutions/public/11000/900/sol11977 err request_module messages at startup time (CR104325) When you start up a system, you might see some of the following error messages.

Specifically, data that arrives when the iRule is suspended does not trigger an additional CLIENT_DATA event. Time-limited (evaluation) product module support With version 10.0.0 of the software, you can evaluate the add-on product modules Application Security Manager, WebAccelerator™ system, Protocol Security Module, and WAN Optimization Module. There is no workaround for this issue. This issue occurs if the system is running BIOS firmware earlier than build 461, and the VIPRION unit is upgraded to version 10.0.0 with the management interface connected to a subnet

You are logged on to the management port of the system you want to upgrade. https://devcentral.f5.com/wiki/TMSH.HomePage.ashx There is no workaround for this issue. NTLM profile for optimized network performance A new NT LAN Manager (NTLM) profile within BIG-IP Local Traffic Manager optimizes network performance when the system is processing NTLM HTTP traffic. New iRules commands This release includes a number of iRules™ enhancements, such as support for logic-execution timers and name/value lookup tables, and enhanced support for read-only global variables on CMP-enabled systems.

Issuing either command without the optional show argument takes the system offline or online. http://colinmeldrum.com/tcl-error/tcl-error-f5.html Editable VLAN tags With this release, you can now change the VLAN tag that you initially assigned to a VLAN without having to delete and then recreate the VLAN. SCF with different hostname value than system (CR102008) If you have a Single Configuration File (SCF) that contains a different hostname value than the system, you cannot automatically roll forward that For other installations, the system stores the installation log file as /var/log/liveinstall.log. [ Top ] Upgrading from earlier versions How you upgrade from earlier versions depends on the version of software

bd restart and Tcl error messages (CR100240) When the bd process restarts, the system stops all internal connections. Email check failed, please try again Sorry, your blog cannot share posts by email. Traffic statistics and the b pva 0.0 command (CR82189) In this release, the b pva 0.0 command shows traffic statistics. http://colinmeldrum.com/tcl-error/tcl-last-error.html The number and type of modules that can be run simultaneously is strictly enforced through licensing.

Share this:LinkedInPocketRedditGoogleTwitterEmail Related F5, programming, TCL Complexity vs Security Wipebook - A Portable Whiteboard 10 Responses to iRules/Tcl - Watch the Comments What Lies Beneath November 25, 2014 at 10:59 pm These messages are benign, and you can safely ignore them. To accomplish the change, you can use the Configuration utility, or you can use the command line to set the provisioning level to None for all other modules, and then set

For more information, see SOL7066: Overview of VLAN failsafe.

CPU usage when pvad monitors many nodes (CR94039) When the pvad service queries a very large number of objects (for example, 2000 nodes), the pvad service might use as much as HA Connection with peer established messages during upgrade (CR109301) If you have state mirroring enabled, when you upgrade one unit of a redundant system, the system post messages until both systems The Inband health monitor provides passive monitoring of nodes or pool members as part of a client request. Although you can access the browser window scroll bars to view the contents of the grayed-out screen, none of the options are active.

When you update from software version 9.3.x or 9.4.x to 10.x, you cannot use the Software Management screens in the Configuration utility. Always specify the netmask when specifying the cluster management IP address if you plan ever to use cluster member addresses. Warning:Do not use the 10.x installation methods (the Software Management screens, the b software commands, or the image2disk utility) to install/downgrade to 9.x software or operate on partitions. http://colinmeldrum.com/tcl-error/tcl-tk-error.html When you use the command line for the same operation, the system presents and error: When a Dedicated provision level is set, all other module's provision levels must be set to

Perfect for testing, when you might need more debug output, or you want to run a slightly different set of actions. When that user logs back on, the system writes to the catalina.out file error messages such as com.f5.mcp.io.McpIOException: java.io.EOFException: Error while reading message at. UDP checksum in IPv4 fragment (CR107852) On BIG-IP 8400 and 8800 platforms, IPv4 fragments of a large User Datagram Protocol (UDP) datagram will be incorrectly modified at offset 6 from the Using vim helped me pick up what was going on.

An application template corresponds to a particular application, such as Citrix® Presentation Server™, and provides a fast, efficient way to configure the BIG-IP system to process the associated traffic. Upon activation and configuration, the evaluation module operates as full-featured software for a specific length of time. Reply Lindsay Hill December 2, 2014 at 10:23 am # You're right that ‘#' comments out the whole line, but that then makes the whole script invalid, because of imbalanced braces. The messages are entirely benign, and you can safely ignore them.

If you do not, the system posts an error message.