Home > Error Code > Teradata Error Code 12

Teradata Error Code 12

Contents

When you provide a value for the WorkingDatabase, we issue the SQL DATABASE request under the covers. The User Guide gives info on accessingthe error tables, but when I try to SELECT from the tables using BTEQ, I am told that the table is being loaded. Its missing here and teh steps there after but directly returns error code. I had SET RECORD VARTEXT in my mind while typing my response. http://colinmeldrum.com/error-code/teradata-multiload-error-code-12.html

In most cases the error is detected before a database operation has interacted with the database. Your use of this Teradata website is governed by the Privacy Policy and the Terms of Use, including your rights to materials on this website, the rights you grant to your Care must be taken to identify the error properly to determine whether a restart is possible and to configure the utility scripts properly for restarts. Defined: 15, Received: 1280 =================================================================== = = = Logoff/Disconnect = = = ===================================================================**** 14:27:29 Logging off all sessions**** 14:27:33 Total processor time used = '1.15625 Seconds' . http://datawarehouse.ittoolbox.com/groups/technical-functional/teradata-l/teradata-utility-returned-with-error-code-12-1737160

Teradata Utility Returned With Error Code 12. Aborting On Its Behalf

here is the script ------------------------------------------------ SESSIONS 4; ERRLIMIT 25; LOGON VIVALDI/username,password; DATABASE MY_DB; /* START IMPORTING FROM LINE 2 */ RECORD 2; /* DATA IS DELIMITED BY A | */ SET Plz help me understand. Highest return code encountered = '12'. **** 09:55:56 FastLoad Paused Tags (2) Tags:fastexportfastload 0 Kudos Reply All forum topics Previous Topic Next Topic 5 REPLIES Santanu84 Enthusiast Mark as New Bookmark The utilities allow checkpoints to be established to prevent the re-execution of database operations that have completed before an error caused an interruption.

Highest return code encountered = '12'.**** 14:27:33 FastLoad Pausedcheers,Young chap 0 Kudos Reply All forum topics Previous Topic Next Topic 5 REPLIES Adeel_Chaudhry Teradata Employee Mark as New Bookmark Subscribe Subscribe A user error is usually a programming or configuration error in the load utility script. A restarted step will not re-execute the database interactions that occurred before the error. The Teradata Utility Returned With Error Code 8 A job control system can parse the output logs to determine and classify the database errors (beyond the scope of this series of articles).

To start fresh, I droppedall the error log tables in both DB's and deleted all files in the checkpoint directory.Then, when transferring datato the "new" database (different than the user's default), Teradata Error Code 12 In Ab Initio In each case the job scheduling and control system should allow a job to be started at a step that was executing when an error occurred and it should allow a All Rights Reserved. https://community.teradata.com/t5/Tools/TPT-return-code-12-during-INSERT/m-p/53281 All rights reserved.

Aswini Roy asked Nov 29, 2007 | Replies (3) While extracting data from database through ab initio, i am getting the below error...please help me as i have very little knowledge Highest Return Code Encountered = '12' Thanks Mike P.S. Start : 09:58:09 - WED APR 02, 2014 . Severe errors terminate a load utility job.

Teradata Error Code 12 In Ab Initio

Examples of error and restart handling for the following utilities are included in this series: Fastload Multiload Tpump Teradata Parallel Transporter (TPT) Load operator Update operator Stream operator In most cases http://community.teradata.com/forum/tools/fast-export-and-fast-load-error More Data Warehouse Groups Your account is ready. Teradata Utility Returned With Error Code 12. Aborting On Its Behalf Aswini Roy replied Nov 29, 2007 Thanks Frank....I deceased the max sessons number to 1... Teradata Error Code 12 Fastexport Highest return code encountered = '0'.Fast Export OUTPUT:144 981 144 981 144 981 144 981 144 981 144 981 144 981 144 981 144 981 144 981 FastLoad.LOGON jugal/jbhatt,jugal;drop table DB.Employees_History;CREATE

Contact Us | Privacy Policy | Terms of Use | Send Feedback | Teradata.com Copyright © 2004-2015 Teradata Corporation. weblink This series of articles focuses on the error handling functionality and restart capabilities of the Teradata database and the Teradata data load utilities. Is there perhaps another way to set the working database? In this case the programming error can be corrected and the operation can be re-run. Error Code 12 In Teradata Fastload

It needs to be decreased to something lower than the max allowed for your TD database. C:\Program Files\Teradata\Client\13.10\Teradata Parallel Transporter\logs>tlogvi ew -j XG_MEDMINING_OR_MANUFACTURER-615 TPT_INFRA: TPT04101: Warning: TMSM failed to initialize Teradata Parallel Transporter Coordinator Version 13.10.00.04 Teradata Parallel Transporter Executor Version 13.10.00.04 Teradata Parallel Transporter SQL DDL A step that is re-run will re-execute all database interactions in that step and continue with succeeding steps. navigate here The Privacy Policy and Terms of Use for this Teradata website changed effective September 8, 2016.

The Privacy Policy and Terms of Use for this Teradata website changed effective September 8, 2016. The application logic may restrict increases to 20%. Loading Table Using Update Table Component With Mload Utility Error while loading into Teradata table using thru PT-UPDATE mode Extract from Teradata fails when using 'FastExport' Error while loading data from

Community Teradata Community Browse Register · Sign In · Help MLOAD returns error code 12 without logging into RDBMS Teradata Applications All communityThis

Options Subscribe to RSS Feed Mark Topic as New Mark Topic as Read Float this Topic to the Top Bookmark Subscribe Printer Friendly Page nvk_kumaran Fan Mark as New Bookmark Subscribe I am getting a error in FastLoad. I could not find any info on status 12 in the TPT User Guide. In most case the error can be corrected and the load utility restarted at the point where the failure occurred.

Start : 12:09:27 - TUE MAY 26, 2015 . In most cases the conditions that cause the error must be corrected and the operation must be re-executed. Sessions: 4 session(s). . his comment is here No spaces please The Profile Name is already in use Password Notify me of new activity in this group: Real Time Daily Never Keep me informed of the latest: White Papers

The way that I am specifying the new database is using the WorkingDatabase attribute. This job cannot be continued or restarted. =================================================================== = we sud define afixed length of char. 0 Kudos Reply feinholz Teradata Employee Mark as New Bookmark Subscribe Subscribe to RSS Feed Get Direct Link Print Email to a Friend Report I have given create privileges to dbc and i was successful. 0 Kudos Reply Teradata Links Teradata.com Teradata Partners Support & Forums Support Portal / TaYS Teradata Aster Community Communities

In this case the error must be classified and reported by the database client. Once you identify the log table you should be able to drop it. These capabilities combined with a well designed high availability architecture allow a Teradata Active Enterprise Intelligence (AEI) system to meet the service level objectives required to support mission critical business processes. Highest return code encountered = '12'.Press any key to continue . . .Hope this helps 0 Kudos Reply Sudheer05 Enthusiast Mark as New Bookmark Subscribe Subscribe to RSS Feed Get Direct

Programming Error – Programming errors represent errors in data load scripts or programs that are executing data access logic. The Teradata group is no longer active. 1737160 Related Discussions Teradata Error Code 12 Error while loading into Teradata table using thru FASTLOAD in Ab Initio Error in Teradata Multiload Error